Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.603
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38563169

RESUMO

Objective:To preliminarily study the practical value of Indocyanine green(ICG) molecular fluorescence imaging technology in nasal endoscopic tumor surgery. Methods:Five patients with tumors related to nasal sinuses, orbital wall and skull base in the Department of Otolaryngology head and Neck Surgery, General Hospital of Xinjiang Military Command from December 2022 to April 2023 were enrolled. Among them, 3 were benign tumors and 2 were malignant tumors. All patients underwent surgery under the guidance of ICG molecular fluorescence imaging. ICG was administered intravenously through cubital vein at a dose of 0.5 mg/kg 12 to 24 h before surgery. Tumors were labeled by fluorescence imaging during the operation. surgeons cleared the tumor tissue strictly according to the labeled range and depth, malignant tumors were further expanded and cleaned according to pathology results. Results:All 5 patients achieved accurate tumor localization with the aid of fluorescence imaging technology. Resections were performed with reference to fluorescent labeling boundaries, all patients achieved complete tumor cleanup or negative margins. Conclusion:For tumor-related surgery under nasal endoscopy, ICG molecular fluorescence imaging technology can not only achieve accurate real-time positioning, but also provide evidence for surgeons to judge tumor boundaries. Therefore, we believe that the technology should have certain practical value in nasal endoscopic tumor surgery.


Assuntos
Verde de Indocianina , Neoplasias , Humanos , Corantes Fluorescentes , Endoscopia/métodos , Imagem Óptica/métodos
2.
J Nanobiotechnology ; 22(1): 146, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566213

RESUMO

Thrombotic diseases impose a significant global health burden, and conventional drug-based thrombolytic therapies are encumbered by the risk of bleeding complications. In this study, we introduce a novel drug-free nanomedicine founded on tea polyphenols nanoparticles (TPNs), which exhibits multifaceted capabilities for localized photothermal thrombolysis. TPNs were synthesized through a one-pot process under mild conditions, deriving from the monomeric epigallocatechin-3-gallate (EGCG). Within this process, indocyanine green (ICG) was effectively encapsulated, exploiting multiple intermolecular interactions between EGCG and ICG. While both TPNs and ICG inherently possessed photothermal potential, their synergy significantly enhanced photothermal conversion and stability. Furthermore, the nanomedicine was functionalized with cRGD for targeted delivery to activated platelets within thrombus sites, eliciting robust thrombolysis upon laser irradiation across diverse thrombus types. Importantly, the nanomedicine's potent free radical scavenging abilities concurrently mitigated vascular inflammation, thus diminishing the risk of disease recurrence. In summary, this highly biocompatible multifunctional nanomaterial holds promise as a comprehensive approach that combines thrombolysis with anti-inflammatory actions, offering precision in thrombosis treatment.


Assuntos
Nanomedicina , Trombose , Humanos , Polifenóis/farmacologia , Chá , Terapia Trombolítica , Verde de Indocianina/farmacologia , Verde de Indocianina/uso terapêutico , Inflamação/tratamento farmacológico , Trombose/tratamento farmacológico
3.
J Gastrointest Surg ; 28(4): 351-358, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38583883

RESUMO

BACKGROUND: Anastomotic leakage (AL) is a determining factor of morbidity and mortality after esophagectomy. Adequate perfusion of the gastric conduit is crucial for AL prevention. This study aimed to determine whether intraoperative angiography using indocyanine green (ICG) fluorescence improves the incidence of AL after McKeown minimally invasive esophagectomy (MIE) with gastric conduit via the substernal route (SR). METHODS: This retrospective cohort study included 120 patients who underwent MIE with gastric conduit via SR for esophageal cancer between February 2019 and April 2023. Of 120 patients, 88 experienced intraoperative angiography using ICG (ICG group), and 32 patients experienced intraoperative angiography without ICG (no-ICG group). Baseline characteristics and operative outcomes, including AL as the main concern, were compared between the 2 groups. In addition, the outcomes among patients in the ICG group with different levels of fluorescence intensity were compared. RESULTS: The ICG and no-ICG groups were comparable in baseline characteristics and operative outcomes. There was no significant difference between the 2 groups regarding the rate of AL (31.0% vs 37.5%; P = .505), median dates of AL (9 vs 9 days; P = .810), and severity of AL (88.9%, 11.11%, and 0.0% vs 66.7%, 16.7%, and 16.7% for grades I, II, and III, respectively; P = .074). Patients in the ICG group with lower intensity of ICG had higher rates of leakage (24.6%, 39.3%, and 100% in levels I, II, and III of ICG intensity, respectively; P = .04). CONCLUSION: The use of ICG did not seem to reduce the rate of AL. However, abnormal intensity of ICG fluorescence was associated with a higher rate of AL, which implies a predictive potential.


Assuntos
Neoplasias Esofágicas , Verde de Indocianina , Humanos , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Estudos Retrospectivos , Estômago/diagnóstico por imagem , Estômago/cirurgia , Estômago/irrigação sanguínea , Fístula Anastomótica/diagnóstico por imagem , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Imagem Óptica/métodos , Anastomose Cirúrgica/efeitos adversos
5.
Chron Respir Dis ; 21: 14799731241246802, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590151

RESUMO

Measuring respiratory and locomotor muscle blood flow during exercise is pivotal for understanding the factors limiting exercise tolerance in health and disease. Traditional methods to measure muscle blood flow present limitations for exercise testing. This article reviews a method utilising near-infrared spectroscopy (NIRS) in combination with the light-absorbing tracer indocyanine green dye (ICG) to simultaneously assess respiratory and locomotor muscle blood flow during exercise in health and disease. NIRS provides high spatiotemporal resolution and can detect chromophore concentrations. Intravenously administered ICG binds to albumin and undergoes rapid metabolism, making it suitable for repeated measurements. NIRS-ICG allows calculation of local muscle blood flow based on the rate of ICG accumulation in the muscle over time. Studies presented in this review provide evidence of the technical and clinical validity of the NIRS-ICG method in quantifying respiratory and locomotor muscle blood flow. Over the past decade, use of this method during exercise has provided insights into respiratory and locomotor muscle blood flow competition theory and the effect of ergogenic aids and pharmacological agents on local muscle blood flow distribution in COPD. Originally, arterial blood sampling was required via a photodensitometer, though the method has subsequently been adapted to provide a local muscle blood flow index using venous cannulation. In summary, the significance of the NIRS-ICG method is that it provides a minimally invasive tool to simultaneously assess respiratory and locomotor muscle blood flow at rest and during exercise in health and disease to better appreciate the impact of ergogenic aids or pharmacological treatments.


Assuntos
Verde de Indocianina , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Verde de Indocianina/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Músculo Esquelético , Taxa Respiratória , Fluxo Sanguíneo Regional/fisiologia
6.
World J Urol ; 42(1): 206, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561548

RESUMO

OBJECTIVE: Identification of superficial inguinal lymph nodes during low-risk penile cancer surgery using near-infrared (NIR) fluorescence to improve the accuracy of lymph-node dissection and reduce the incidence of missed micrometastases and complications. METHODS: Thirty-two cases were selected, which were under the criteria of < T1, and no lymph-node metastasis was found with magnetic resonance imaging (MRI) detection. Two groups were randomly divided based on the fluorescence technique, the indocyanine green (ICG) group and the non-ICG group. In the ICG group, the ICG preparation was subcutaneously injected into the edge of the penile tumor 10 min before surgery, and the near-infrared fluorescence imager was used for observation. After the lymph nodes were visualized, the superficial inguinal lymph nodes were removed first, and then, the penis surgery was performed. The non-ICG group underwent superficial inguinal lymph-node dissection and penile surgery. RESULTS: Among the 16 patients in the ICG group, we obtained 11 lymph-node specimens using grayscale values of images (4.13 ± 0.72 vs. 3.00 ± 0.82 P = 0.003) along with shorter postoperative healing time (7.31 ± 1.08 vs. 8.88 ± 2.43 P = 0.025), and less lymphatic leakage (0 vs. 5 P = 0.04) than the 16 patients in the non-ICG group. Out of 11, 3 lymph nodes that are excised were further grouped into fluorescent and non-fluorescent regions (G1/G2) and found to be metastasized. CONCLUSION: Near-infrared fluorescence-assisted superficial inguinal lymph-node dissection in penile carcinoma is accurate and effective, and could reduce surgical complications.


Assuntos
Neoplasias Penianas , Humanos , Masculino , Corantes , Verde de Indocianina , Excisão de Linfonodo/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia , Metástase Linfática/patologia , Neoplasias Penianas/diagnóstico por imagem , Neoplasias Penianas/cirurgia , Neoplasias Penianas/patologia , Biópsia de Linfonodo Sentinela/métodos
7.
ACS Appl Mater Interfaces ; 16(14): 17253-17266, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38557012

RESUMO

Extending molecular imaging into the shortwave-infrared (SWIR, 900-1400 nm) region provides deep tissue visualization of biomolecules in the living system resulting from the low tissue autofluorescence and scattering. Looking at the Food and Drug Administration-approved and clinical trial near-infrared (NIR) probes, only indocyanine green (ICG) and its analogues have been approved for biomedical applications. Excitation wavelength less than 800 nm limits these probes from deep tissue penetration and noninvasive fluorescence imaging. Herein, we present the synthesis of ICG-based π-conjugation-extended cyanine dyes, ICG-C9 and ICG-C11 as biocompatible, and water-soluble SWIR-emitting probes with emission wavelengths of 922 and 1010 nm in water, respectively. Also, ICG-, ICG-C9-, and ICG-C11-based fluorescent labeling agents have been synthesized for the development of SWIR molecular imaging probes. Using the fluorescence of ICG, ICG-C9, and ICG-C11, we demonstrate three-color SWIR fluorescence imaging of breast tumors by visualizing surface receptors (EGFR and HER2) and tumor vasculature in living mice. Furthermore, we demonstrate two-color SWIR fluorescence imaging of breast tumor apoptosis using an ICG-conjugated anticancer drug, Kadcyla and ICG-C9 or ICG-C11-conjugated annexin V. Finally, we show long-term (38 days) SWIR fluorescence imaging of breast tumor shrinkage induced by Kadcyla. This study provides a general strategy for multiplexed fluorescence molecular imaging with biocompatible and water-soluble SWIR-emitting cyanine probes.


Assuntos
Neoplasias da Mama , Corantes Fluorescentes , Animais , Camundongos , Humanos , Feminino , Ado-Trastuzumab Emtansina , Verde de Indocianina , Imagem Molecular , Imagem Óptica/métodos , Neoplasias da Mama/diagnóstico por imagem
8.
Neuroimaging Clin N Am ; 34(2): 261-270, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38604710

RESUMO

Cerebrovascular surgery has many intraoperative imaging modalities available. Modern technologies include intraoperative digital subtraction angiogram, indocyanine green (ICG) angiography, relative fluorescent measurement with ICG, and ultrasound. Each of these can be used effectively in the treatment of open aneurysm and arteriovenous malformation surgeries, in addition to arteriovenous fistula surgery, and cerebral bypass surgery.


Assuntos
Verde de Indocianina , Neurocirurgia , Humanos , Angiografia Digital/métodos , Angiografia Cerebral/métodos , Procedimentos Neurocirúrgicos/métodos
9.
Asian J Endosc Surg ; 17(3): e13308, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38622489

RESUMO

Laparoscopic deroofing (LD) for giant liver cysts using indocyanine green (ICG) fluorescence imaging was performed in two patients: a 53-year-old man with a 26-cm, symptomatic cyst and a 50-year-old woman with a 13-cm, symptomatic cyst. ICG fluorescence imaging can be used to easily identify the boundary between the liver parenchyma and the liver cyst. No postoperative bile leakage was observed in both patients. ICG fluorescence imaging is expected to become a desirable procedure in LD for giant liver cysts to reduce the occurrence of perioperative complications.


Assuntos
Cistos , Laparoscopia , Hepatopatias , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Verde de Indocianina , Laparoscopia/métodos , Cistos/diagnóstico por imagem , Cistos/cirurgia , Cistos/complicações , Imagem Óptica , Fígado
10.
Khirurgiia (Mosk) ; (4): 82-92, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634589

RESUMO

OBJECTIVE: To assess the possibilities of fluorescent detection system in qualitative and quantitative assessment of bowel perfusion in colorectal resections. MATERIAL AND METHODS: From May to August 2023, a single-center pilot cross-sectional unblinded study with inclusion of 18 patients with colon cancer (of left-sided - 12, of right-sided - 6, mean age - 72.9 years, m/w - 61/39%) was conducted. All patients underwent laparoscopic colorectal resections with extracorporeal stage of bowel transection. The evaluation of the bowel's ICG perfusion was conducted to assist in decision making about the level of its resection. Qualitative (visual) assessment was carried out in all 18 patients, in one patient twice, quantitative assessment of perfusion was conducted in 8 patients (left-sided resections - 6, right-sided hemicolectomy - 2). The qualitative evaluation was performed in real time on the analysis of the color gradient. The time parameters and fluorescence intensity at different level proximally and distally from the resection line were quantitatively estimated: Tstart - time of occurrence of minimal fluorescence in the areas of interest after the ICG injection (sec); Tmax - time to achieve maximum fluorescence intensity after the ICG injection (sec); Tmax-start - time interval between Tstart and Tmax, Imax - level of maximum fluorescence intensity (I). RESULTS: Visual qualitative analysis of fluorescence revealed unsatisfactory perfusion characteristics (black, dark-gray color) in the area planned by the surgeon to anastomose the bowel in 3 of 18 patients (16.6%). When analyzing the quantitative data of this group of patients, there was a 2-6-fold decrease in Imax level, and one patient had an increase in Tmax-start at the level of intended resection compared to the bowel's sections in the favorable zone. In all cases, the final bowel transection was conducted in the area of good perfusion. There was no clinical evidence of anastomotic dehiscence in the study group. CONCLUSION: Intraoperative evaluation of bowel perfusion is an important component of safe anastomosis formation in colorectal surgery. The use of ICG-FA allows to conduct qualitative and quantitative assessment of tissue perfusion of the bowel in order to assist in making intraoperative decisions. Quantitative evaluation of fluorescence provides more objective information about perfusion parameters. Imax and Tmax-start are the most promising quantitative indicators of local bowel's perfusion. Nevertheless, the precise interpretation of the quantitative indicators of ICG perfusion needs to be clarified.


Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Anastomose Cirúrgica , Fístula Anastomótica/cirurgia , Colectomia , Neoplasias Colorretais/cirurgia , Estudos Transversais , Angiofluoresceinografia , Verde de Indocianina , Perfusão , Masculino , Feminino , Idoso
11.
Cancer Rep (Hoboken) ; 7(4): e2053, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577849

RESUMO

INTRODUCTION: Chylothorax (CT) is a rare yet serious complication after esophagectomy. Identification of the thoracic duct (TD) during esophagectomy is challenging due to its anatomical variation. Real-time identification of TD may help to prevent its injury. Near infra-red imaging with Indocyanine green (ICG) is a novel technique that recently has been used to overcome this issue. METHODS: Patients who underwent minimally invasive esophagectomy for esophageal cancer were divided into two groups with and without ICG. We injected ICG into bilateral superficial inguinal lymph nodes. Identification of TD and its injuries during the operation was evaluated and compared with the non-ICG group. RESULTS: Eighteen patients received ICG, and 18 patients underwent surgery without ICG. Each group had one (5.5%) TD ligation. In the ICG group injury was detected intraoperative, and ligation was done at the site of injury. In all cases, the entire thoracic course of TD was visualized intraoperatively after a mean time of 81.39 min from ICG injection to visualization. The Mean extra time for ICG injection was 11.94 min. In the ICG group, no patient suffered from CT. One patient in the non-ICG group developed CT after surgery that was managed conservatively. According to Fisher's exact test, there was no significant association between CT development and ICG use, possibly due to the small sample size. CONCLUSIONS: This study confirms that ICG administration into bilateral superficial inguinal lymph nodes can highlight the TD and reduce its damage during esophagectomy. It can be a standard method for the prevention of postoperative CT.


Assuntos
Quilo , Verde de Indocianina , Humanos , Ducto Torácico/diagnóstico por imagem , Ducto Torácico/cirurgia , Ducto Torácico/patologia , Esofagectomia/efeitos adversos , Fluorescência
12.
J Nanobiotechnology ; 22(1): 180, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622591

RESUMO

To address the limitations of traditional photothermal therapy (PTT)/ photodynamic therapy (PDT) and real-time cancer metastasis detection, a pH-responsive nanoplatform (NP) with dual-modality imaging capability was rationally designed. Herein, 1 H,1 H-undecafluorohexylamine (PFC), served as both an oxygen carrier and a 19F magnetic resonance imaging (MRI) probe, and photosensitizer indocyanine green (ICG) were grafted onto the pH-responsive peptide hexahistidine (H6) to form H6-PFC-ICG (HPI). Subsequently, the heat shock protein 90 inhibitor, gambogic acid (GA), was incorporated into hyaluronic acid (HA) modified HPI (HHPI), yielding the ultimate HHPI@GA NPs. Upon self-assembly, HHPI@GA NPs passively accumulated in tumor tissues, facilitating oxygen release and HA-mediated cell uptake. Once phagocytosed by lysosomes, protonation of H6 was triggered due to the low pH, resulting in the release of GA. With near-infrared laser irradiation, GA-mediated decreased HSP90 expression and PFC-mediated increased ROS generation amplified the PTT/PDT effect of HHPI@GA, leading to excellent in vitro and in vivo anticancer efficacies. Additionally, the fluorescence and 19F MRI dual-imaging capabilities of HHPI@GA NPs enabled effective real-time primary cancer and lung metastasis monitoring. This work offers a novel approach for enhanced cancer phototherapy, as well as precise cancer diagnosis.


Assuntos
Neoplasias Pulmonares , Nanopartículas , Fotoquimioterapia , Humanos , Fototerapia/métodos , Verde de Indocianina , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Oxigênio , Concentração de Íons de Hidrogênio , Linhagem Celular Tumoral
13.
Lymphat Res Biol ; 22(2): 120-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593453

RESUMO

Background: Indocyanine green (ICG) lymphography, a key diagnostic tool for lymphedema, is influenced by the dilution process of ICG dye, impacting patient experience. Methods and Results: In our study, we assessed three different ICG diluents-water for injection (WFI), normal saline (NS), and Dextrose® plus human albumin-in five healthy volunteer individuals undergoing superficial lymphography of the upper limb over 3 weeks. Results indicated that NS, as a diluent for ICG, caused the least discomfort during injection, in contrast to WFI, which led to the highest levels of discomfort. Transport time of ICG from the injection site to the axillary lymph nodes was notably shorter in intradermal injections than in subdermal injections. Conclusion: Our findings advocate for using NS as the optimal and cost-effective diluent for ICG, enhancing patient experience.


Assuntos
Verde de Indocianina , Linfedema , Humanos , Linfografia/métodos , Estudos Prospectivos , Conforto do Paciente , Linfonodos/patologia , Linfedema/patologia , Corantes
14.
Lymphat Res Biol ; 22(2): 147-152, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38630993

RESUMO

Background: Recently, the usefulness of lymphatic ultrasound has been reported. It is beneficial not only to identify lymphatic vessels but also to evaluate lymphatic degeneration and diagnose lymphedema. We previously proposed D-CUPS (Doppler, Cross, Uncollapsible, Parallel, and Superficial fascia) to identify the lymphatic vessels on ultrasound. The purpose of this study was to clarify the sensitivity of each index of D-CUPS. Methods: We performed a retrospective study of 27 patients (44 limbs, 98 sites) with lower extremity lymphedema, who underwent lymphaticovenous anastomosis (LVA). We performed a lymphatic ultrasound the day before surgery. We used a linear probe commonly used for venous ultrasound (Noblus EUP-L65; Hitachi Medical Corp., Tokyo, Japan). We applied the D-CUPS index to identify the lymphatic vessels on ultrasound. We checked whether lymphatic vessels consistent with preoperative lymphatic ultrasound findings were observed during the LVA. We also calculated the sensitivity of each D-CUPS index. Results: All the 27 patients were women, with a mean age of 59.7 years. Totally, 98 incisions were made (59 incisions on the thigh and 39 incisions on the lower leg). During LVA, lymphatic vessels consistent with the preoperative lymphatic ultrasound findings were observed at all the sites. The sensitivities of each indicator of D-CUPS were 100.0%, 100.0%, 68.4%, 19.4%, and 100.0%, respectively. Conclusion: The sensitivity was 100.0% in D, C, and S. Although each index separately was not perfect, by combining them appropriately, we were able to identify lymphatic vessels with certainty.


Assuntos
Vasos Linfáticos , Linfedema , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Tela Subcutânea , Ultrassonografia , Linfedema/cirurgia , Linfografia , Vasos Linfáticos/diagnóstico por imagem , Verde de Indocianina
15.
J Biomed Opt ; 29(4): 046002, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38633382

RESUMO

Significance: Head and neck squamous cell carcinoma (HNSCC) has a particularly poor prognosis. Improving the surgical resection boundary, reducing local recurrence, and ultimately ameliorating the overall survival rate are the treatment goals. Aim: To obtain a complete surgical resection (R0 resection), we investigated the use of a fluorescent imaging probe that targets the integrin subtype αvß6, which is upregulated in many kinds of epithelial cancer, using animal models. Approach: αvß6 expression was detected using polymerase chain reaction (PCR) and immunoprotein blotting of human tissues for malignancy. Protein expression localization was observed. αvß6 and epidermal growth factor receptor (EGFR) were quantified by PCR and immunoprotein blotting, and the biosafety of targeting the αvß6 probe material was examined using Cell Counting Kit-8 assays. Indocyanine green (ICG) was used as a control to determine the localization of the probe at the cellular level. In vivo animal experiments were conducted through tail vein injections to evaluate the probe's imaging effect and to confirm its targeting in tissue sections. Results: αvß6 expression was higher than EGFR expression in HNSCC, and the probe showed good targeting in in vivo and in vitro experiments with a good safety profile. Conclusions: The ICG-αvß6 peptide probe is an exceptional and sensitive imaging tool for HNSCC that can distinguish among tumor, normal, and inflammatory tissues.


Assuntos
Neoplasias de Cabeça e Pescoço , Verde de Indocianina , Animais , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Linhagem Celular Tumoral , Peptídeos/metabolismo , Receptores ErbB , Imunoproteínas
16.
Khirurgiia (Mosk) ; (4): 105-111, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634591

RESUMO

OBJECTIVE: To prove from a clinical and economic point of view the expediency of using ICG cholangiography in patients with «difficult¼ laparoscopic cholecystectomy for the prevention of damage to the bile ducts. MATERIAL AND METHODS: The results of treatment of 173 patients with cholelithiasis at various levels of health care providing were analyzed with regard to assessment of indicators of surgery complexity, developed complications and economic costs. RESULTS: The effectiveness of the original scale of «difficult¼ laparoscopic cholecystectomy has been proved. The financial and economic costs of treatment of patients with damage of biliary ducts and patients with cholelithiasis without development of complications have been analyzed and evaluated. A comparative description of financial costs for patients with «difficult¼ laparoscopic cholecystectomy with the use of ICG-cholangiography has been given. A program on care delivery for patients suffering from cholelithiasis in the conditions of region with regard to safety and economic effectiveness has been developed. CONCLUSION: The implementation of this program provides the minimization of postoperative complications and fatality at all levels of surgical care delivery. It has been established that a rational approach to reducing the number of biliary ducts damages is their prevention by prediction of «difficult¼ laparoscopic cholecystectomy and performance of such interventions in medical organizations of III level with the possibility of modern technologies use.


Assuntos
Colecistectomia Laparoscópica , Colelitíase , Humanos , Colecistectomia Laparoscópica/métodos , Verde de Indocianina , Colangiografia/métodos , Ductos Biliares , Colelitíase/cirurgia
17.
JAMA Netw Open ; 7(4): e246548, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639939

RESUMO

Importance: Unintended tumor-positive resection margins occur frequently during minimally invasive surgery for colorectal liver metastases and potentially negatively influence oncologic outcomes. Objective: To assess whether indocyanine green (ICG)-fluorescence-guided surgery is associated with achieving a higher radical resection rate in minimally invasive colorectal liver metastasis surgery and to assess the accuracy of ICG fluorescence for predicting the resection margin status. Design, Setting, and Participants: The MIMIC (Minimally Invasive, Indocyanine-Guided Metastasectomy in Patients With Colorectal Liver Metastases) trial was designed as a prospective single-arm multicenter cohort study in 8 Dutch liver surgery centers. Patients were scheduled to undergo minimally invasive (laparoscopic or robot-assisted) resections of colorectal liver metastases between September 1, 2018, and June 30, 2021. Exposures: All patients received a single intravenous bolus of 10 mg of ICG 24 hours prior to surgery. During surgery, ICG-fluorescence imaging was used as an adjunct to ultrasonography and regular laparoscopy to guide and assess the resection margin in real time. The ICG-fluorescence imaging was performed during and after liver parenchymal transection to enable real-time assessment of the tumor margin. Absence of ICG fluorescence was favorable both during transection and in the tumor bed directly after resection. Main Outcomes and Measures: The primary outcome measure was the radical (R0) resection rate, defined by the percentage of colorectal liver metastases resected with at least a 1 mm distance between the tumor and resection plane. Secondary outcomes were the accuracy of ICG fluorescence in detecting margin-positive (R1; <1 mm margin) resections and the change in surgical management. Results: In total, 225 patients were enrolled, of whom 201 (116 [57.7%] male; median age, 65 [IQR, 57-72] years) with 316 histologically proven colorectal liver metastases were included in the final analysis. The overall R0 resection rate was 92.4%. Re-resection of ICG-fluorescent tissue in the resection cavity was associated with a 5.0% increase in the R0 percentage (from 87.4% to 92.4%; P < .001). The sensitivity and specificity for real-time resection margin assessment were 60% and 90%, respectively (area under the receiver operating characteristic curve, 0.751; 95% CI, 0.668-0.833), with a positive predictive value of 54% and a negative predictive value of 92%. After training and proctoring of the first procedures, participating centers that were new to the technique had a comparable false-positive rate for predicting R1 resections during the first 10 procedures (odds ratio, 1.36; 95% CI, 0.44-4.24). The ICG-fluorescence imaging was associated with changes in intraoperative surgical management in 56 (27.9%) of the patients. Conclusions and Relevance: In this multicenter prospective cohort study, ICG-fluorescence imaging was associated with an increased rate of tumor margin-negative resection and changes in surgical management in more than one-quarter of the patients. The absence of ICG fluorescence during liver parenchymal transection predicted an R0 resection with 92% accuracy. These results suggest that use of ICG fluorescence may provide real-time feedback of the tumor margin and a higher rate of complete oncologic resection.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Estudos de Coortes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Verde de Indocianina , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Margens de Excisão , Imagem Óptica/métodos , Estudos Prospectivos , Pessoa de Meia-Idade
18.
BMC Surg ; 24(1): 117, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643065

RESUMO

BACKGROUND: This study investigated the clinical application of the indocyanine green (ICG) fluorescence navigation technique in bile duct identification during laparoscopic common bile duct exploration (LCBDE) for complex hepatolithiasis. METHODS: Eighty patients with complex hepatolithiasis were admitted to our department between January 2022 and June 2023 and randomly divided into control and observation groups. The control group underwent conventional LCBDE, while the observation group underwent LCBDE guided by ICG fluorescence. RESULTS: Intraoperatively, the observation group had shorter operation and search times for the common bile duct (CBD), as well as reduced intraoperative blood loss and fewer complications, such as conversion to laparotomy and various injuries (gastroduodenal, colon, pancreatic, and vascular) than the control group, with statistical significance (P < 0.05). Postoperatively, the observation group had lower rates of postoperative bile leakage, abdominal infection, postoperative hemorrhage, and residual stone than the control group. Additionally, the observation group demonstrated significantly shorter times for resuming flatus, removal of the abdominal drainage tube, and hospitalization than the control group, with statistical significance (P < 0.05). CONCLUSION: ICG fluorescence navigation technology effectively visualizes the bile duct, improves its identification rate, shortens the operation time, prevents biliary tract injury, and reduces the occurrence of complications.


Assuntos
Coledocolitíase , Laparoscopia , Litíase , Hepatopatias , Humanos , Verde de Indocianina , Coledocolitíase/cirurgia , Hepatopatias/cirurgia , Litíase/cirurgia , Estudos Retrospectivos , Laparoscopia/métodos , Ducto Colédoco/cirurgia , Tempo de Internação
19.
Gan To Kagaku Ryoho ; 51(3): 317-319, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38494817

RESUMO

The indocyanine green(ICG)fluorescence navigation that we have standardized for laparoscopic liver resection is useful for partial liver resection and anatomical liver resection for liver cancer, and extended cholecystectomy for gallbladder cancer. In partial liver resection we believe that it is possible to secure a resection margin by not exposing the fluorescence emission around the tumor. In anatomical liver resection, real-time navigation becomes possible by transecting the liver at the boundary between colored and non-colored area, which contributes to precise liver surgery. In extended cholecystectomy, it is difficult to inject ICG from the cystic artery which was performed in open liver resection. So, we encircled Calot's triangle using the Glissonean approach from the ventral side of the gallbladder plate and then taped the hilar Glissonean pedicles. After clamping this tape, ICG was injected into the vein. By using this method, laparoscopic surgery has become possible in the same way as open surgery. With further spread in the future, it is hoped that liver resection using ICG fluorescence navigation will not only be precise, but also safe and highly curative surgery.


Assuntos
Colecistectomia Laparoscópica , Laparoscopia , Neoplasias Hepáticas , Humanos , Fluorescência , Laparoscopia/métodos , Verde de Indocianina , Hepatectomia/métodos , Fígado , Neoplasias Hepáticas/cirurgia , Colecistectomia Laparoscópica/métodos
20.
Mol Imaging Biol ; 26(2): 233-239, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38448775

RESUMO

PURPOSE: A critical step in cell-based therapies is determining the exact position of transplanted cells immediately post-transplant. Here, we devised a method to detect cell transplants immediately post-transplant, using a clinical gadolinium-based contrast agent. These cells were detected as hyperintense signals using a clinically familiar T1-weighted MRI protocol. PROCEDURES: HEK293 cells were stably transduced to express human OATP1B3, a hepatic organic anion transporting polypeptide that transports Gd-EOB-DTPA into cells that express the transporters, the intracellular accumulation of which cells causes signal enhancement on T1-weighted MRI. Cells were pre-labeled prior to injection in media containing Gd-EOB-DTPA for MRI evaluation and indocyanine green for cryofluorescence tomography validation. Labeled cells were injected into chicken hearts, in vitro, after which MRI and cryofluorescence tomography were performed in sequence. RESULTS: OATP1B3-expressing cells had substantially reduced T1 following labeling with Gd-EOB-DTPA in culture. Following their implantation into chicken heart, these cells were robustly identified in T1-weighted MRI, with image-derived injection volumes of cells commensurate with intended injection volumes. Cryofluorescence tomography showed that the areas of signal enhancement in MRI overlapped with areas of indocyanine green signal, indicating that MRI signal enhancement was due to the transplanted cells. CONCLUSIONS: OATP1B3-expressing cells can be pre-labeled with Gd-EOB-DTPA prior to injection into tissue, affording the use of clinically familiar T1-weighted MRI to robustly detect cell transplants immediately after transplant. This procedure is easily generalizable and has potential advantages over the use of iron oxide based cell labeling agents and imaging procedures.


Assuntos
Verde de Indocianina , Transportadores de Ânions Orgânicos , Humanos , Rastreamento de Células , Células HEK293 , Gadolínio DTPA , Meios de Contraste , Fígado , Imageamento por Ressonância Magnética/métodos , Transplante de Células
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...